Material Safety Data
Sheet
(To the purchaser this MSDS contains important
environmental, safety and health information for your employees who will be
using this product. Please be sure that this information is given to them. If
you resell this product a copy of the MSDS should be given to the
buyer.)
Manufacturer's Name :
M.P.Carbon Pvt. Ltd. Address : 322-324 URLA Industrial Area,
Raipur-493221, Chattisgarh State, India Phone :
91-771-232-3419 Fax :
91-771-232-6308
Section 1
Trade Name |
Century
Excelmelt |
Chemical and Common
Name(s) |
Carbon Bonded SIC
Refractory |
Formula |
C+SIC+AL203+SI+GLASS |
Section
2
Potential Ingredients |
Percentage |
Remarks |
SIC |
30-35 |
Total
Dust |
Graphite |
25-35 |
Total
Dust |
AL203 |
4-5 |
Total
Dust |
Silicon /
Ferro |
4-12 |
Total
Dust |
SIO2 |
0-10 |
Respirable
Dust |
silicates |
3-6 |
|
C (Carbon) |
10-16 |
|
The ingredients are not hazardous and
no exposure will occur with normal use.
Section 3: Physical
Data
Boiling
Point |
N/A |
Specific
Gravity |
2.2-2.6gm/cc |
Vapour
Density |
N/A |
Volatiles |
N/A |
Vapour
Density |
N/A |
Evapouration
Rate |
N/A |
Solubility |
Negligible |
Melting
Point |
N/A |
Appearance and
Odour |
Black Granular Solid
& No Odour |
Section 4: Fire and
Explosion Hazard Data
Flash Point |
N/A |
Flammable Limits |
Lower: N/A Upper:
N/A |
Extinguishing Media |
Not Flammable |
Special Firefighting
Procedure |
None Required |
Unusual Explosion and Fire
Hazards |
None |
Section 5: Reactivity
Data
Stability |
Stable |
Conditions to
avoid |
None |
Incompatiability |
None |
Hazardous decomposition
products |
None |
Hazardous polymerisation |
Will not occur |
Conditions to avoid |
None |
Section 6: Health Hazard
Data
Listed as a carcinogen |
No |
Symptons and effects if this product
is cut or ground of over exposure |
Nusiance dust so created may cause
irritation of respiratory system. Prolonged exposure a pulmonary
problems.respiratable crystaline silica may cause delayed lung infection.
|
Emergency and first aid
procedures |
None |
Section 7: Spill or Leak
Procedure
Steps to be taken incase
material is leaked or spilled |
Collect and sweep
up |
Waste disposable
method |
Use a sanitary landfill
in accordance with local, state or central
regulations |
Section 8: Recommended
Control Measures
Respiratory
Protection |
If cutting or grinding
article collect and sweep up use approved respirators vetilation
local |
Mechanical |
N/A |
Special |
N/A |
Protective
gloves |
Recommended, not
necessary |
Eye protection use
goggles if cutting etc other protection equipment |
N/A |
Special protective
measures for repairs and maintance of contaminated equipment. |
N/A |
Section 9: Special
Precaution
Precaution to betaken in
handling and storing |
None |
Care has been taken in preparation of
this information and M. P. Carbon Pvt. Ltd. extends no warrantees, makes no
representation and assumes no responsibility of this information for any
purchasers use or any other consequences of its use. |