Material Safety Data Sheet

(To the purchaser this MSDS contains important environmental, safety and health information for your employees who will be using this product. Please be sure that this information is given to them. If you resell this product a copy of the MSDS should be given to the buyer.)

Manufacturer's Name : M.P.Carbon Pvt. Ltd.
Address : 322-324 URLA Industrial Area, Raipur-493221, Chattisgarh State, India    
Phone : 91-771-232-3419
Fax : 91-771-232-6308

Section 1

Trade Name Century Excelmelt
Chemical and Common Name(s)  Carbon Bonded SIC Refractory
Formula C+SIC+AL203+SI+GLASS

Section 2

Potential Ingredients Percentage Remarks
SIC 30-35 Total Dust
Graphite 25-35 Total Dust
AL203 4-5 Total Dust
Silicon / Ferro 4-12 Total Dust
SIO2 0-10 Respirable Dust
silicates 3-6
C (Carbon) 10-16

The ingredients are not hazardous and no exposure will occur with normal use.

Section 3: Physical Data

Boiling Point N/A
Specific Gravity 2.2-2.6gm/cc
Vapour Density N/A
Volatiles N/A
Vapour Density N/A
Evapouration Rate N/A
Solubility Negligible
Melting Point N/A
Appearance and Odour Black Granular Solid & No Odour

Section 4: Fire and Explosion Hazard Data

Flash Point N/A
Flammable Limits Lower: N/A Upper: N/A
Extinguishing Media Not Flammable
Special Firefighting Procedure None Required
Unusual Explosion and Fire Hazards None

Section 5: Reactivity Data

Stability Stable
Conditions to avoid None
Incompatiability None
Hazardous decomposition products None
Hazardous polymerisation Will not occur
Conditions to avoid None

Section 6: Health Hazard Data

Listed as a carcinogen No
Symptons and effects if this product is cut or ground of over exposure Nusiance dust so created may cause irritation of respiratory system. Prolonged exposure a pulmonary problems.respiratable crystaline silica may cause delayed lung infection.
Emergency and first aid procedures None

Section 7: Spill or Leak Procedure

Steps to be taken incase material is leaked or spilled Collect and sweep up
Waste disposable method Use a sanitary landfill in accordance with local, state or central regulations

Section 8: Recommended Control Measures

Respiratory Protection If cutting or grinding article collect and sweep up use approved respirators vetilation local
Mechanical N/A
Special N/A
Protective gloves Recommended, not necessary
Eye protection use goggles if cutting etc other protection equipment N/A
Special protective measures for repairs and maintance of  contaminated equipment. N/A

Section 9: Special Precaution

Precaution to betaken in handling and storing None

Care has been taken in preparation of this information and M. P. Carbon Pvt. Ltd. extends no warrantees, makes no representation and assumes no responsibility of this information for any purchasers use or any other consequences of its use.